24V 3A switching power supply module 72W medical device power supply AC220V-DC24V
Technical Parameter:
Model No.: | MOL-U60S5 | MOL-U65S12 | MOL-U65S15 | MOL-U65S24 | MOL-U65S36 | MOL-U65S48 | |
Output characteristics | Output Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated current | 8A | 5A | 4A | 2.5A | 2A | 1.5A | |
Current range | 0-10A | 0-5.5A | 0-4.5A | 0-3A | 0-2.2A | 0-1.5A | |
Ripple | <100 mVp-p | <100 mVp-p | <130 mVp-p | <130 mVp-p | <220 mVp-p | <200 mVp-p | |
Output Precision | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Voltage regulation rate | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
load Adjustment rate | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated Power | 40W | 60W | 60W | 60W | 72W | 72W | |
Adjustable output range | Can choose the adjustable or fixed constant voltage output | ||||||
Build, rise, hold time | 300ms, 50ms, 50ms/220VAC | ||||||
Input characteristics | Input voltage range | 100-264V AC | |||||
Input Current | <1.0A (Average current 0.4-0.9A) | ||||||
Frequency Range | 47-63HZ | ||||||
Efficiency | 74% | 81% | 82.50% | 84.50% | 87.60% | 88% | |
Starting impulse current | cold start <50A/230VAC | ||||||
Leakage current | <0.6mA/220VAC | ||||||
Protection characteristics | Over power protection | 150-170% rated power,Automatic recovery after fault removal | |||||
Overvoltage protection | VH1:>50% | ||||||
DC short circuit protection | power supply Intermittent Gap,Power recovery after Eliminate short circuits | ||||||
Environmental parameters | Working temperature, humidity | _15℃ - +50℃ @100% load, +60℃ @60% load; 20%-90% RH | |||||
Storage temperature, humidity | _20℃- +85℃ 10%-95% RH | ||||||
Safety and EMC standards | EMI safety standards | MEET Gb4943 | |||||
Withstand voltage | I/P-O/P:2.5KVAC 1min | ||||||
Insulation resistance | I/P-O/P: 500VDC/100M Ohms | ||||||
Other | Dimension | 108x62x30mm | |||||
Weight | 146g | ||||||
Remarks | 1.All technical parameters are measured under the condition of 220VAC input, Rated load environment 25℃, Humidity 70%. | ||||||
2.Precision: Including setting tolerance, voltage adjustment rate, load adjustment rate. | |||||||
3.Ripple test: Use the twisted wire of 30cm to connect power supply and load, | |||||||
0.1uF and 47uF capacitors on the load side, Measured with a 20MH oscilloscope at the load end. | |||||||
4.Voltage regulation rate: Under rated load conditions, the input voltage is measured from low to high. | |||||||
5.Load Regulation rate: The measured output changes from 0% load to 100% load. | |||||||
6.Every line Can output maximum current, but the total load cannot exceed the maximum output power. |
Dimension:
Copyright © 2007-2017 Mo-Light Electronics Technology Co., Ltd. All rights reserved.
Addres:2nd Floor,Building14,Shangsha Industrial Park,Futian District,Shenzhen,Guangdong Province,China
Tel: 0086-755-83206580 Fax:0086-755-83206581
E-mail: sales01@molight-led.com
LED Corn Light|LED Flood Light|LED Tube|LED Panel|LED Downlight|LED High Bay Light|LED Retrofit Light|LED Street Light